Key product
AC Input
Input rating100 to 240 VAC, 50/60 Hz, 15 – 7.5 A, 100 to 120 VAC, 440 Hz, 15 AOperating voltage range

90 to 264 VAC

Nominal input frequency

50 Hz/60 Hz/400 Hz

Operating frequency range

47 to 440 Hz

Efficiency

85% typical

Over-current protection

Internal fuse in line

Main power disconnect

The AC power cable provides main power disconnect. Do not position the equipment so that it is difficult to disconnect the power cord. The front-panel power switch causes the internal chassis power supply to provide DC power to the PXI Express backplane. With the Timing and Synchronization upgrade, you also can use the rear-panel 15-pin connector and inhibit mode switch to control the internal chassis power supply.

Chassis Cooling
Module cooling

Forced air circulation (positive pressurization) through three 210 CFM fans

Module slot airflow direction

Bottom of module to top of module

Module intake

Rear of chassis

Module exhaust

Top of chassis

Slot cooling capacity

82 W

Secondary cooling

Forced air circulation (positive pressurization) through one 70 CFM fan

Side intake

Right side of chassis

Side exhaust

Left side of chassis

Power supply cooling

Forced air circulation through two integrated fans

Power supply intake

Rear of chassis

Reviews

There are no reviews yet.

Be the first to review “PXIe-1095, 18-slot 3U PXI Express Chassis with Timing and Synchronization Option (785971-01)”