Key product
AC Input
Input rating100 VAC to 240 VAC, 50 Hz/60 Hz, 3 A to 1.5 AOperating voltage range1

90 VAC to 264 VAC

Nominal input frequency

50 Hz/60 Hz

Operating frequency range1

47 Hz to 63 Hz

Efficiency

93.5% typical

Over-current protection

Internal fuse in line

Main power disconnect

The AC power cable provides main power disconnect. Do not position the equipment so that it is difficult to disconnect the power cord. The front-panel power switch causes the internal chassis power supply to provide DC power to the PXI Express backplane.

Over-current protection

All outputs are protected from short circuit and overload. They recover and return to regulation when the overload is removed and the power is cycled.

Over-voltage protection

+3.3 V clamped at 3.7 V to 4.3 V, +5 V clamped at 5.7 V to 6.5 V, +12 V clamped at 13.4 V to 15.6 V
Chassis Cooling
Module cooling

Forced air circulation (positive pressurization) through two 42 CFM fans

Module slot airflow direction

Bottom of module to top of module

Module intake

Right side or bottom of chassis

Module exhaust

Left side or top2 of chassis

Slot cooling capacity

58 W
Operating Environment
Ambient temperature range
When all peripheral modules require ≤38 W cooling capacity per slot

0 °C to 50 °C

When any peripheral module requires >38 W to 58 W cooling capacity per slot

0 °C to 40 °C

Relative humidity range

20% to 80%, noncondensing